url: /docs/guides/deployment.md
description: How to deploy the Electric sync engine.
---

# Deployment

How to deploy the [Electric sync engine](/primitives/postgres-sync), with links to integration docs for specific platforms like [Supabase](/docs/integrations/supabase), [Neon](/docs/integrations/neon), [Render](/docs/integrations/render) and [AWS](/docs/integrations/aws).

> \[!TIP] Electric Cloud – the simplest way to use Electric
> The simplest way to use Electric is via the [Electric Cloud](/cloud), which is a simple, scalable, low-cost, managed Electric hosting service.

## The ingredients of a successful deployment

An Electric deployment has three main components. Your Postgres database, the Electric sync service and your app.

Electric connects to your Postgres using a `DATABASE_URL`. Your app connects to Electric [over HTTP](/docs/api/http), usually using a [Client library](/docs/api/clients/typescript).

As a result, there are three ingredients to a successful Electric deployment:

1. you need to be [running a Postgres database](#_1-running-postgres)
2. you need to [run and connect the Electric sync service](#_2-running-electric)
3. you need your app/client to [connect to Electric over HTTP](#_3-connecting-your-app)

### Proxying requests to Electric

You also often want to proxy requests to Electric through your API, or other proxy. For example, to implement [auth](./auth) and/or [caching](/docs/api/http#caching). In these cases, you'll also need to deploy your API and/or proxy layer in front of Electric.

Note also that, when running Electric behind a CDN, you may want your proxy in front of the CDN. This is where primitives like [edge functions](/docs/integrations/supabase#sync-into-edge-function) and [edge workers](/docs/integrations/cloudflare#workers) can be very useful.

### Securing data access

By default, Electric exposes public access to the contents of your database. You generally don't want to expose the contents of your database, so you need to [lock down access](/docs/guides/security#secure-data-access) to the Electric HTTP API.

See the [Security guide](/docs/guides/security) for information.

## 1. Running Postgres

You can use ***any standard Postgres***, version 14 and above.

This includes Postgres you host yourself, or Postgres hosted by managed database hosting providers, including:

* [Supabase](/docs/integrations/supabase)
* [Neon](/docs/integrations/neon)
* [AWS (RDS and Aurora)](/docs/integrations/aws)
* [GCP (Cloud SQL and Alloy)](/docs/integrations/gcp)
* [Digital Ocean](/docs/integrations/digital-ocean)
* [Crunchy](/docs/integrations/crunchy)

Postgres must have [logical replication](https://www.postgresql.org/docs/current/logical-replication-config.html) enabled. You also need to connect as a database role that has the [`REPLICATION`](https://www.postgresql.org/docs/current/logical-replication-security.html) attribute.

### Data model compatibility

Electric is compatible with ***any Postgres data model***.

Electric will work as a drop on to any existing data model. There are no limitations on the database features, data types or extensions you can use.

### Connecting to Postgres

You connect to Postgres using a [`DATABASE_URL`](/docs/api/config#database-url) env var. This connection string contains your user credentials and an `sslmode` parameter.

You usually want to connect directly to Postgres and not via a connection pool. This is because Electric uses logical replication and most connection poolers don't support it. (pgBouncer does support logical replication, [as of version 1.23](https://www.pgbouncer.org/changelog.html#pgbouncer-123x) so this may change in future).

You can optionally provide a separate [`ELECTRIC_POOLED_DATABASE_URL`](/docs/api/config#electric-query-database-url) env var, which can use a pooler and will be used for all queries other than replication.

To force Electric to verify the database server's certificate when connecting to it using TLS, set the [`ELECTRIC_DATABASE_CA_CERTIFICATE_FILE`](/docs/api/config#electric-database-ca-certificate-file) config option.

> \[!Tip] Troubleshooting common errors
> If you get a TCP connection error saying `non-existing domain - :nxdomain` or `network is unreachable - :enetunreach` then you may need to connect using IPv6. You can enable this by setting [`ELECTRIC_DATABASE_USE_IPV6=true`](/docs/api/config#database-use-ipv6).
>
> If you get a TCP connection `timeout` error then make sure you're connecting directly to Postgres and not via a connection pool. For example, when using [Supabase](/docs/integrations/supabase) you need to untick their "Use connection pooling" option on the database settings page.
>
> If you're using IPv6 with Docker, then assuming the machine you're running Electric on has IPv6 connectivity, you may also need to enable IPv6 for the Docker daemon. You can do this by [defining an IPv6-capable network](https://docs.docker.com/engine/daemon/ipv6/#create-an-ipv6-network)) in your Compose file and then adding the `networks` key to the Electric service definition.

### Database resources

Electric creates a logical replication [publication](https://www.postgresql.org/docs/current/logical-replication-publication.html) and [replication slot](https://www.postgresql.org/docs/current/logical-replication-subscription.html#LOGICAL-REPLICATION-SUBSCRIPTION-SLOT) inside Postgres. These are called `electric_publication_default` and `electric_slot_default` by default. You can configure the name suffix using the [`ELECTRIC_REPLICATION_STREAM_ID`](/docs/api/config#replication-stream-id) env var.

If the database role that Electric connects to Postgres as doesn't have the required privileges to create or update the publication, Electric will check that the publication exists in the database and that it is in the right state, meaning that any table for which a shape request is created must have been added to the publication by hand, in advance. This behaviour can also be enforced with the [`ELECTRIC_MANUAL_TABLE_PUBLISHING`](/docs/api/config#electric-manual-table-publishing) config option.

When running, Electric also keeps a pool of active database connections open. The size of this pool defaults to `20` and can be configured using [`ELECTRIC_DB_POOL_SIZE`](/docs/api/config#electric-db-pool-size).

> \[!Tip] Cleaning up resources
> If you decide to stop using Electric with a given Postgres database or switch to a different database but keep the old one around, make sure to clean up both the publication and the replication slot.
>
> See this [troubleshooting advice](./troubleshooting#wal-growth-mdash-why-is-my-postgres-database-storage-filling-up) for details.

## 2. Running Electric

The [Electric sync engine](/primitives/postgres-sync) is an Elixir web service, packaged using Docker.

You can deploy it anywhere you can run a container with a filesystem and exposed HTTP port. This includes cloud and application hosting platforms like:

* [AWS](/docs/integrations/aws)
* [GCP](/docs/integrations/gcp)
* [Digital Ocean](/docs/integrations/digital-ocean)
* [Fly.io](/docs/integrations/fly)
* [Render](/docs/integrations/render)

### Docker container

Images are deployed to Docker Hub at [electricsql/electric](https://hub.docker.com/r/electricsql/electric).

### Optimizing for disk

Electric caches [Shape logs](/docs/api/http#shape-log) and metadata on the filesystem. Your Electric host must provide a persistent filesystem. Ideally this should be large, fast and locally mounted, such as a NVMe SSD. If you're configuring a machine and you want to optimise it for Electric, the factors to optimise for, in order of important, are:

1. disk speed — low latency, high throughput reads and writes
2. memory
3. CPU

For example, on AWS, [Storage Optimized](https://aws.amazon.com/ec2/instance-types/#Storage_Optimized) instances such as the `i3en.large`, or on Hetzner the [SX-line](https://www.hetzner.com/dedicated-rootserver/matrix-sx/) of dedicated servers would both be great choices.

### Configuring storage

The path to Electric's persistent storage can be configured via the [`ELECTRIC_STORAGE_DIR`](/docs/api/config#electric-storage-dir) environment variable, e.g. `ELECTRIC_STORAGE_DIR=/var/lib/electric/persistent`. Electric will create the directory at that path if it doesn't exist yet. However, you need to make sure that the OS user that Electric is running as has the necessary permissions in the parent directory.

The file system location configured via `ELECTRIC_STORAGE_DIR` and the data Electric stores there must survive sync service's restarts. For example, when using Kubernetes, you'll want to create a persistent volume and attach it to your Electric deployment.

> \[!Tip] Clear one, clear the other
> The persistent state that Electric maintains in Postgres (via the logical replication publication and replication slot) **must** stay in sync with the shape data cached on disk by Electric.
>
> If you change the value of `ELECTRIC_STORAGE_DIR` or switch to a different `DATABASE_URL` at any point, you **must** clean up the other location by hand, whether it's removing a directory tree on disk or dropping the replication slot and publication in Postgres.

> \[!Tip] How much storage space?
> Electric trades storage for low memory use and fast sync. How much storage you need is highly application dependent. We encourage you to test with your own workload.
>
> We plan to implement [compaction](https://github.com/electric-sql/electric/issues/1582) and other features to limit and optimise storage use, such as [garbage collecting LRU shapes](https://github.com/electric-sql/electric/issues/1529).

### HTTP port

Electric provides an HTTP API exposed on a configurable [`ELECTRIC_PORT`](/docs/api/config#electric-port). You should make sure this is exposed to the Internet.

### Health checks

Electric provides a health check endpoint at `/v1/health` that can be used for liveness and readiness probes. This endpoint does not require authentication, so it works even when [`ELECTRIC_SECRET`](/docs/api/config#electric-secret) is set.

The endpoint returns a JSON response with a `status` field:

| HTTP Status | Response | Meaning |
|-------------|----------|---------|
| `200` | `{"status": "active"}` | Electric is fully operational and ready to serve requests |
| `202` | `{"status": "waiting"}` | Electric is waiting to acquire the replication lock |
| `202` | `{"status": "starting"}` | Electric is starting up and establishing connections |

For **liveness probes**, any response (200 or 202) indicates the service is alive.

For **readiness probes**, you should check for a `200` status code to ensure Electric is fully ready to handle shape requests.

Example health check using curl:

```shell
curl http://localhost:3000/v1/health
# {"status":"active"}
```

#### Kubernetes probes

When deploying Electric on Kubernetes, note that standard `httpGet` probes consider any 2xx response as success. This means an `httpGet` readiness probe would incorrectly mark the pod as ready when Electric returns `202` (still starting up).

For **liveness probes**, `httpGet` works fine since any response indicates the service is alive:

```yaml
livenessProbe:
  httpGet:
    path: /v1/health
    port: 3000
  initialDelaySeconds: 10
  periodSeconds: 10
  timeoutSeconds: 2
```

For **readiness probes**, use an `exec` probe to check for exactly HTTP 200. The Electric container includes `curl`:

```yaml
readinessProbe:
  exec:
    command:
      - sh
      - -c
      - |
        test "$(curl -so /dev/null -w '%{http_code}' http://localhost:3000/v1/health)" = "200"
  initialDelaySeconds: 5
  periodSeconds: 10
  timeoutSeconds: 2
  failureThreshold: 3
```

This ensures the pod is only marked ready when Electric is fully operational and ready to serve shape requests.

### Observability

Electric supports [OpenTelemetry](https://opentelemetry.io/) for exporting traces, with built-in support for [Honeycomb.io](https://www.honeycomb.io/). Metrics are also available in StatsD and Prometheus formats.

See the [Telemetry reference](/docs/reference/telemetry#opentelemetry) for configuration details.

### Caching proxy

Electric is designed to run behind a caching proxy, such as [Nginx](https://nginx.org/en), [Caddy](https://caddyserver.com), [Varnish](https://varnish-cache.org) or a CDN like [Cloudflare](https://www.cloudflare.com/en-gb/application-services/primitives/cdn) or [Fastly](https://www.fastly.com/primitives/cdn). You don't *have* to run a proxy in front of Electric but you will benefit from radically better performance if you do.

See the [Caching section](/docs/api/http#caching) of the HTTP API docs for more information.

## 3. Connecting your app

You can then connect your app to Electric [over HTTP](/docs/api/http). Typically you use a [Client library](/docs/api/clients/typescript) and configure the URL in the constructor, e.g.:

```ts
const stream = new ShapeStream({
  url: `https://your-electric-service.example.com/v1/shape`,
  params: {
    table: `foo`,
  },
})
const shape = new Shape(stream)
```

You can connect to Electric from any language/environment that speaks HTTP. See the [HTTP API](/docs/api/http) and [Client docs](/docs/api/clients/typescript) for more information.